Whether you want to enjoy a broad view of the flames in the comfort of your living room during a romantic evening or simply to benefit from impressive heat in cold weather, the Inspire will charm you as much by its aesthetics as its 77% optimal performance. With its particle emission rate as low as 1.54 g/h and its high-performance combustion system, environmentalists have never been as happy with wood heating.

 

Required Accessories:

Requires the addition of one each of (A) required accessories to complete the unit

A:

  • AC01020  Narrow Faceplate (U Shape)
  • AC01021  32" x 50" Cuttable Faceplate (16 GA)
  • AC01022  Narrow Faceplate

Features

Features

Fuel type : Dry cordwood
Recommended heating area (sq. ft.): 500 - 2,100
Overall firebox volume : 2.4
EPA loading volume (cu. ft.): 2.02
Maximum burn time : 8 h
Maximum heat output (dry cordwood) : 75,000 BTU/h (22 kW)
Overall heat output rate (min. to max.): 14,800 BTU/h (4.34 kW) to 28,600 BTU/h (8.38 kW))
Average overall efficiency (EPA cribs/Douglas fir) : N.A. (HHV) N.A. (LHV)
Average overall efficiency (dry cordwood) : 69% (HHV) 74% (LHV)
Optimum efficiency : 77 %
Average particulate emissions rate : 1.54 g/h
Average CO : 89.4 g/h

Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(Average Overall Efficieny) As measured per CSA B415.1-10 stack loss method.

(HHV) Higher Heating Value of the fuel.

(LHV) Lower Heating Value of the fuel.

Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

Optimum overall efficiency at a specific burn rate (LHV).

 This appliance is officially tested and certified by an independent agency.

 

Specifications

Specifications

Combustion technology: Non-catalytic
High-efficiency certified appliance: Yes, EPA 2020 approved
Maximum log length: 20"
Log positioning: Over width
Chimney diameter: 6"
Type of chimney: Liner - ULC-S635, CAN/ULC-S640, UL1777
Minimum chimney height (feet): 12'
Baffle type: C-Cast
Approved for a mobile home installation: No
Shipping Weight: 420 lb (191 kg)
Door type: Single, glass with steel frame
Glass type: Ceramic glass
Glass surface – dimensions (Width X Height): 24 13/16" X 18 1/2"
Glass air-wash system: Yes
Premium quality blower included (CFM): 176
Overall dimension (Height): 24"
Overall dimension (Width): 28 1/2"
Overall dimension (Depth): 20 3/4"
Door opening – dimension (Height): 8 1/4"
Door opening - dimension (Width): 20"
Firebox – dimension (Height): 11 3/4"
Firebox – dimension (Width): 21"
Firebox – dimension (Depth): 16 3/4"
Firebox lined with refractory bricks for better heat distribution: Yes
Stainless-steel secondary-air system improving gas combustion: Yes
Adjustable threaded legs: No
Steel thickness – body: 3/16"
Steel thickness – top: 3/8"
Fireplace opening – minimum (Height): 24 5/8"
Fireplace opening – minimum (Width): 29"
Fireplace opening – minimum (Depth): 20 3/4"
USA standard (emissions): EPA Method 28
Canadian Standard (emissions): CSA B415.1-10
USA standard (safety): UL 1482, UL 737
Canadian standard (safety): ULC S628
Tested and listed as per applicable standards: By an accredited laboratory (CAN/USA)
Warranty: Limited lifetime

Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)

Clearance – top (measured from the platform on which the appliance is installed)** N.A. N.A.
Clearance – combustible side mantle to unit 9" 9"
Clearance – combustible top mantle to unit 27" 27"
Clearance – combustible side wall to unit 16" 16"
Clearance – minimum floor protection in front of the appliance 18" 16"
Clearance – top shelf to unit 27" 27"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

Literature

Support

Support

Manuals: Operation and Installation

Owner's Manual Osburn Inspire Wood Insert

To top