Osburn 1700 Wood Stove

Description

Description

*Pricing reflects additional freight costs to Alaska.

Designed to meet the needs of smaller spaces, the Osburn 1700 combines robustness and elegance to allow you to enjoy your heating experience with confidence. This unit is equipped with high-density bricks, a cast iron door, a built-in ash pan, a top heat deflector that redirects heat to the front of the unit, and side panels to reduce its clearances. Exceeding air quality regulations with emissions as low as 1.26 g/h, the Osburn 1700's efficiency will save you time and money.

 

Required Accessories:

Requires the addition of one each of (A) and (B) required accessories to complete the unit

A:

  • OA10249  Black Door Overlay
  • OA10250  Brushed Nickel Door Overlay

B:

  • OA10244  Pedestal With Ash Drawer
  • OA10247  Black Cast Iron Traditional Legs With Ash Drawer
  • OA10248  Brushed Nickle Cast Iron Traditional Legs With Ash Drawer

 

OPTIONS:

  • AC01000  130 CFM Blower With Variable Speed Control (Thermodisc Included)

Features

Features

Fuel type: Dry cordwood
Recommended heating area (sq.ft.): 500-1,800
Firebox volume (cu. ft.): 1.9
Maximum burn time: 6 h
Maximum heat output (dry cordwood): 65,000 BTU/h (19 kW)
Overall heat output rate (min. to max.): 15,650 BTU/h (4.6 kW) to 23,300 BTU/h (6.83 kW)
Average overall efficiency (EPA cribs / Douglas fir):

N.A (HHV) N.A. (LHV)

Average overall efficiency (dry cordwood):

70% (HHV) 75% (LHV)

Optimum efficiency: 78 %
Average particulate emissions rate: 1.26 g/h
Average CO: 58 g/h

Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

 Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

As measured per CSA B415.1-10 stack loss method.

Higher Heating Value of the fuel.

Lower Heating Value of the fuel.

Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

Optimum overall efficiency at a specific burn rate (LHV).

This appliance is officially tested and certified by an independent agency.

 

Specifications

Specifications

Combustion technology Non-catalytic
High-efficiency EPA certified appliance Yes, EPA 2020 approved
Maximum log length 18"
Log positioning Over width
Chimney diameter 6"
Flue outlet diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet) 15'
Baffle type C-Cast
Approved for an alcove installation Yes
Approved for a mobile home installation Yes, with fresh air intake
Shipping Weight 331 lb (150 kg)
Door type Single, glass with cast iron frame
Glass type Glass type
Glass surface – dimensions (Width X Height) 15 3/4" x 9 3/8"
Glass air-wash system Yes
Overall dimension (Height) 30 3/8"
Overall dimension (Width) 24 7/8"
Overall dimension (Depth) 23 1/4"
Door opening – dimension (Height) 8 3/4"
Door opening - dimension (Width) 17 1/4"
Firebox – dimension (Height) 11 7/8"
Firebox – dimension (Width) 19 5/8"
Firebox – dimension (Depth) 13 1/2"
Firebox lined with refractory bricks for better heat distribution Yes
Stainless-steel secondary-air system improving gas combustion Yes
Steel thickness – body 3/16"
Steel thickness – top 5/16"
USA standard (emissions) EPA
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1482, UL 737
Canadian standard (safety) ULC S627
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime

 

Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)

                                                                                     Canada                    USA

  Single wall pipe Double wall pipe Single wall pipe Double wall pipe
Clearance – back wall 14 1/2" 6" 13" 6"
Clearance - corner 12" 12" 12" 12"
Clearance – side wall 10" 10" 10" 10"
Clearance – top (measured from the platform on which the appliance is installed)** 84" 84" 84" 84"
Clearance – minimum floor protection in front of the appliance 18"   16"  

*The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.