*Pricing reflects additional freight costs to Alaska.

The Inspire offers a style that will surely withstand variable trends with these pure lines of balanced proportions, allowing the brand  Osburn to easily compare to European-style products. This more contemporary look is available on a steel base, soapstone, or even a minimalist base for those who prefer to place the unit directly on a non-combustible podium. Equipped with a 2.3 cubic feet firebox and an outside air intake, this unit will meet the requirements of domestic energy standards, not to mention that a mobile home installation is permitted.

 

Required Accessories:

Requires the addition of one each of (A) and (B) required accessories to complete the unit

A:

  • OA10242  Black Decorative Side Panel

B:

  • OA10240  Black Steel Base
  • OA10243  Minimalist Base
     

Options:

  • AC03095  Blower Assembly With Variable Speed Control (UP TO 130 CFM)

Features

Features

Fuel type :

Dry cordwood

Recommended heating area (sq. ft.): 500 - 2,100
Overall firebox volume : 2.4
EPA loading volume (cu. ft.): 2.02
Maximum burn time : 8 h
Maximum heat output (dry cordwood) :  75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.): 14,800 BTU/h (4.34 kW) to 28,600 BTU/h (8.38 kW)
Average overall efficiency (EPA cribs/Douglas fir) : N.A. (HHV) N.A. (LHV)
Average overall efficiency (dry cordwood):  69% (HHV) 74 % (LHV)
Optimum efficiency :  77 %
Average particulate emissions rate : 1.54 g/h
Average CO : 89.4 g/h

Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(Average Overall Efficieny) As measured per CSA B415.1-10 stack loss method.

(HHV) Higher Heating Value of the fuel.

(LHV) Lower Heating Value of the fuel.

Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

Optimum overall efficiency at a specific burn rate (LHV).

 This appliance is officially tested and certified by an independent agency.

 

Specifications

Specifications

Combustion technology: Non-catalytic
High-efficiency certified appliance: Yes, EPA 2020 approved
Maximum log length: 20"
Log positioning: Over width
Chimney diameter: 6"
Flue outlet diameter: 6"
Type of chimney: CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet): 12'
Baffle type: C-Cast
Approved for an alcove installation: Yes
Approved for a mobile home installation: Yes, with fresh air intake
Shipping Weight: 537 lb (244 kg)
Door type: Single, glass with steel frame
Glass type: Ceramic glass
Glass surface – dimensions (Width X Height): 20 1/4" X 9 1/2"
Glass air-wash system: Yes
Overall dimension (Height): 36 9/16"
Overall dimension (Width): 27 7/8"
Overall dimension (Depth): 24 15/16"
Door opening – dimension (Height): 8 3/8"
Door opening - dimension (Width): 20"
Firebox – dimension (Height): 11 15/16"
Firebox – dimension (Width): 21 1/4"
Firebox – dimension (Depth): 17 11/16"
Firebox lined with refractory bricks for better heat distribution: Yes
Stainless-steel secondary-air system improving gas combustion: Yes
Model: Pedestal
Steel thickness – body: 3/16"
Steel thickness – top: 5/16"
Easy-to-access ash drawer: Yes
USA standard (emissions): EPA Method 28
Canadian Standard (emissions): CSA B415.1-10
USA standard (safety): UL 1482, UL 737
Canadian standard (safety): ULC S627
Tested and listed as per applicable standards: By an accredited laboratory (CAN/USA)
Warranty: Limited lifetime

 

Minimum clearances to combustibles* 
(Data expressed in inches. 1 inch = 25.4 mm)

                                                                                    Canada                      USA

  Single wall pipe Double wall pipe

Single wall pipe

Double wall pipe
Clearance – back wall 14 ½" 6" 11" 6"
Clearance - corner 10" 7" 10" 7"
Clearance – side wall 17" 17" 16" 16"
Clearance – top (measured from the platform on which the appliance is installed)** 84" 84" 84" 84"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.