The Osburn 3300 represents the essence of eco-friendly and efficient heating. With an emission rate of 0.95 g/h, this non-catalytic wood stove is among the cleanest on the market and represents an environmentally friendly source of energy. This north-south loading model will keep your family warm all night long, even in very cold weather, thanks to its power of 95,000 BTU/h.
Required Accessories:
Requires the addition of one each of (A) and (B) required accessories to complete the
A:
- OA10260 Black Door Overlay
- OA10261 Brushed Nickel Door Overlay
B:
- OA10262 Pestal With Ash Drawer
- OA10263 Black Cast Iron Traditional Legs With Ash Drawer
- OA10265 Brushed Nickel Cast Iron Traditional Legs With Ash Drawer
- OA10266 Black Cast Iron Straight Legs With Ash Drawer
Options:
AC01000 130 CFM Blower With Variable Speed Control (THERMODISC INCLUDED)
Features
Features
Fuel type : | Dry cordwood |
Recommended heating area (sq. ft.): | 900 - 2,300 |
Overall firebox volume : | 3.3 |
EPA loading volume (cu. ft.): | 2.67 |
Maximum burn time : | 10 h |
Maximum heat output (dry cordwood) : | 90,000 BTU/h (26.4 kW) |
Overall heat output rate (min. to max.): | 15,841 BTU/h (4.64 kW) to 57,041 BTU/h (16.72 kW) |
Average overall efficiency (EPA cribs/Douglas fir) : | N.A. (HHV) N.A. (LHV) |
Average overall efficiency (dry cordwood) : | 71.1 % (HHV) 76.6 % (LHV) |
Optimum efficiency : | 78 % |
Average particulate emissions rate : | 0.95 g/h |
Average CO : | 61.3 g/h |
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
(Average Overall Efficiency) As measured per CSA B415.1-10 stack loss method.
(HHV) Higher Heating Value of the fuel.
(LHV) Lower Heating Value of the fuel.
Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
Optimum overall efficiency at a specific burn rate (LHV).
This appliance is officially tested and certified by an independent agency.
Specifications
Specifications
Combustion technology: | Non-catalytic |
High-efficiency certified appliance: | Yes, EPA 2020 approved |
Maximum log length: | 20" |
Log positioning: | Over depth |
Chimney diameter: | 6" |
Flue outlet diameter: | 6" |
Type of chimney: | CAN/ULC S629, UL 103 HT (2100 °F) |
Minimum chimney height (feet): | 15' |
Baffle type: | C-Cast |
Approved for a mobile home installation: | Yes, with fresh air intake |
Shipping Weight: | 465 lb |
Door type: | Single, glass with cast iron frame |
Glass type: | Ceramic glass |
Glass surface – dimensions (Width X Height): | 14 1/2" X 11 5/8" |
Glass air-wash system: | Yes |
Overall dimension (Height): | 34" |
Overall dimension (Width): | 24 1/4" |
Overall dimension (Depth): | 30 1/2" |
Door opening – dimension (Height): | 12" |
Door opening - dimension (Width): | 16" |
Firebox – dimension (Height): | 14 1/8" |
Firebox – dimension (Width): | 19" |
Firebox – dimension (Depth): | 21" |
Firebox lined with refractory bricks for better heat distribution: | Yes |
Stainless-steel secondary-air system improving gas combustion: | Yes |
Steel thickness – body: | 3/16" |
Steel thickness – top: | 5/16" |
USA standard (emissions): | EPA |
Canadian Standard (emissions): | CSA B415.1-10 |
USA standard (safety): | UL 1482, UL 737 |
Canadian standard (safety): | ULC S627 |
Tested and listed as per applicable standards: | By an accredited laboratory (CAN/USA) |
Warranty: | Limited lifetime |
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
Canada USA
Single wall pipe | Double wall pipe | Single wall pipe | Double wall pipe | |
Clearance – back wall | 14 1/2" | 6" | 14 1/2" | 6" |
Clearance - corner | 10" | 8" | 10" | 8" |
Clearance – side wall | 12" | 12" | 12" | 12" |
Clearance – top (measured from the platform on which the appliance is installed)** | 84" | 84" | 84" | 84" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.