Osburn, 3300 Wood Stove

Description

Description

The Osburn 3300 represents the essence of eco-friendly and efficient heating. With an emission rate of 0.95 g/h, this non-catalytic wood stove is among the cleanest on the market and represents an environmentally friendly source of energy. This north-south loading model will keep your family warm all night long, even in very cold weather, thanks to its power of 95,000 BTU/h.

 

Required Accessories:

Requires the addition of one each of (A) and (B) required accessories to complete the

A:

  • OA10260  Black Door Overlay
  • OA10261  Brushed Nickel Door Overlay

B:

  • OA10262  Pestal With Ash Drawer
  • OA10263  Black Cast Iron Traditional Legs With Ash Drawer
  • OA10265  Brushed Nickel Cast Iron Traditional Legs With Ash Drawer
  • OA10266  Black Cast Iron Straight Legs With Ash Drawer

Options:

AC01000  130 CFM Blower With Variable Speed Control (THERMODISC INCLUDED)

Features

Features

Fuel type : Dry cordwood
Recommended heating area (sq. ft.): 900 - 2,300
Overall firebox volume : 3.3
EPA loading volume (cu. ft.): 2.67
Maximum burn time : 10 h
Maximum heat output (dry cordwood) : 90,000 BTU/h (26.4 kW)
Overall heat output rate (min. to max.): 15,841 BTU/h (4.64 kW) to 57,041 BTU/h (16.72 kW)
Average overall efficiency (EPA cribs/Douglas fir) : N.A. (HHV) N.A. (LHV)
Average overall efficiency (dry cordwood) : 71.1 % (HHV) 76.6 % (LHV)
Optimum efficiency : 78 %
Average particulate emissions rate : 0.95 g/h
Average CO : 61.3 g/h

Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.

The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(Average Overall Efficiency) As measured per CSA B415.1-10 stack loss method.

(HHV) Higher Heating Value of the fuel.

(LHV) Lower Heating Value of the fuel.

Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

Optimum overall efficiency at a specific burn rate (LHV).

This appliance is officially tested and certified by an independent agency.

 

Specifications

Specifications

Combustion technology: Non-catalytic
High-efficiency certified appliance: Yes, EPA 2020 approved
Maximum log length: 20"
Log positioning: Over depth
Chimney diameter: 6"
Flue outlet diameter: 6"
Type of chimney: CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet): 15'
Baffle type: C-Cast
Approved for a mobile home installation: Yes, with fresh air intake
Shipping Weight: 465 lb
Door type: Single, glass with cast iron frame
Glass type: Ceramic glass
Glass surface – dimensions (Width X Height): 14 1/2" X 11 5/8"
Glass air-wash system: Yes
Overall dimension (Height): 34"
Overall dimension (Width): 24 1/4"
Overall dimension (Depth): 30 1/2"
Door opening – dimension (Height): 12"
Door opening - dimension (Width): 16"
Firebox – dimension (Height): 14 1/8"
Firebox – dimension (Width): 19"
Firebox – dimension (Depth): 21"
Firebox lined with refractory bricks for better heat distribution: Yes
Stainless-steel secondary-air system improving gas combustion: Yes
Steel thickness – body: 3/16"
Steel thickness – top: 5/16"
USA standard (emissions): EPA
Canadian Standard (emissions): CSA B415.1-10
USA standard (safety): UL 1482, UL 737
Canadian standard (safety): ULC S627
Tested and listed as per applicable standards: By an accredited laboratory (CAN/USA)
Warranty: Limited lifetime

 

Minimum clearances to combustibles* 
(Data expressed in inches. 1 inch = 25.4 mm)

                                                                            Canada  USA

  Single wall pipe Double wall pipe Single wall pipe Double wall pipe
Clearance – back wall 14 1/2" 6" 14 1/2" 6"
Clearance - corner 10" 8" 10" 8"
Clearance – side wall 12" 12" 12" 12"
Clearance – top (measured from the platform on which the appliance is installed)** 84" 84" 84" 84"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

Literature

To top